Abstract:Generative models have shown strong potential for positron emission tomography (PET) image reconstruction. Although diffusion model-based reconstruction methods have demonstrated promising performance, they often require many reverse sampling steps with data-consistency updates incorporated into the sampling process. Flow matching offers an attractive alternative because it can directly estimate clean images from intermediate states, allowing data-consistency refinement to be separated from flow propagation. In this work, we proposed flow matching-based PET image reconstruction methods. We first established PET-FlowDPS by incorporating Poisson likelihood guidance with an expectation-maximization (EM)-based preconditioner into the FlowDPS framework. We then proposed a model-based PET reconstruction method that used a pretrained flow matching model as a prior, in which the flow-based prior, PET data refinement, and stochastic propagation were interpreted within an approximate Bayesian framework. Experimental results using [$^{\text{18}}\text{F}$]FDG brain PET datasets showed that the proposed method achieved better bias-variance trade-offs across different dose levels compared with other reference methods. These results demonstrated the potential of flow matching as a generative prior for quantitative PET image reconstruction.
Abstract:Dynamic PET enables the quantitative estimation of physiology-related parameters and is widely utilized in research and increasingly adopted in clinical settings. Parametric imaging in dynamic PET requires kinetic modeling to estimate voxel-wise physiological parameters based on specific kinetic models. However, parametric images estimated through kinetic model fitting often suffer from low image quality due to the inherently ill-posed nature of the fitting process and the limited counts resulting from non-continuous data acquisition across multiple bed positions in whole-body PET. In this work, we proposed a diffusion model-based kinetic modeling framework for parametric image estimation, using the Patlak model as an example. The score function of the diffusion model was pre-trained on static total-body PET images and served as a prior for both Patlak slope and intercept images by leveraging their patch-wise similarity. During inference, the kinetic model was incorporated as a data-consistency constraint to guide the parametric image estimation. The proposed framework was evaluated on total-body dynamic PET datasets with different dose levels, demonstrating the feasibility and promising performance of the proposed framework in improving parametric image quality.