Abstract:Medical foundation models improve generalization when training AI models with limited labeled data, but remain confined to a single specialty, such as pathology or radiology, and to either sparse or dense outputs, such as classification or segmentation. Here, we present CoM$^3$eT (Co-representation Multidimensional Multitask Medical Transformer), a medical vision foundation model that unifies pathology and radiology, sparse and dense predictions, and two- and higher-dimensional inputs by modeling multidimensional context with attention. CoM$^3$eT outperformed other medical foundation models in an open competition spanning five tomographic, four whole-specimen, and three two-dimensional datasets, covering sparse and dense prediction tasks as well as report generation. When adapted across diverse clinical applications, training fewer than 2.5% of parameters achieved performance comparable to full fine-tuning, enabling research without access to high-performance GPU clusters. Applied to federated learning across hospitals, this approach achieved performance comparable to pooled-data training over internet connections and with consumer-grade hardware.
Abstract:Pelvic diseases in women of reproductive age represent a major global health burden, with diagnosis frequently delayed due to high anatomical variability, complicating MRI interpretation. Existing AI approaches are largely disease-specific and lack real-time compatibility, limiting generalizability and clinical integration. To address these challenges, we establish a benchmark framework for disease- and parameter-agnostic, real-time-compatible unsupervised anomaly detection in pelvic MRI. The method uses a residual variational autoencoder trained exclusively on healthy sagittal T2-weighted scans acquired across diverse imaging protocols to model normal pelvic anatomy. During inference, reconstruction error heatmaps indicate deviations from learned healthy structure, enabling detection of pathological regions without labeled abnormal data. The model is trained on 294 healthy scans and augmented with diffusion-generated synthetic data to improve robustness. Quantitative evaluation on the publicly available Uterine Myoma MRI Dataset yields an average area-under-the-curve (AUC) value of 0.736, with 0.828 sensitivity and 0.692 specificity. Additional inter-observer clinical evaluation extends analysis to endometrial cancer, endometriosis, and adenomyosis, revealing the influence of anatomical heterogeneity and inter-observer variability on performance interpretation. With a reconstruction time of approximately 92.6 frames per second, the proposed framework establishes a baseline for unsupervised anomaly detection in the female pelvis and supports future integration into real-time MRI. Code is available upon request (https://github.com/AniKnu/UADPelvis), prospective data sets are available for academic collaboration.