Abstract:Studies of machine-learning-based power-system protection increasingly report near-perfect scores, yet the meaning of those scores depends strongly on the evaluation setting. Protection task, physical scope, measurements, timing, targets, preprocessing, and validation often vary jointly and remain incompletely specified. This paper proposes a standardization-oriented framework that treats evaluation design as part of the scientific contribution. It defines seven required study dimensions: protection objective, physical scope, observability, timing and decision windows, targets and sample validity, validation protocol, and evaluation outputs. The framework is instantiated in a bounded case study on the public PROTECT-90 electromagnetic-transient benchmark, comprising 9022 simulated episodes from a 90 kV double-line topology, for onset-conditioned fault classification and localization. Under centralized sensing, simulation-metadata-aligned 20 ms windows, and episode-grouped validation, a multi-layer perceptron (MLP) achieved a five-fold mean macro-averaged F1 score of 0.991 +/- 0.001 for classification and a localization mean absolute error of 10.20 +/- 0.25% of line length (mean +/- std across episode-grouped folds). Extending the decision horizon to 50 ms preserved this task-dependent performance asymmetry, while reduced observability approximately doubled the MLP localization error but had little effect on classification. A synchronized two-ended conventional locator outperformed the learning locators under its richer clean information set, and measurement degradation showed that clean predictive performance did not determine robustness. The framework turns evaluation assumptions into explicit, reproducible evidence and provides a basis for more comparable, auditable evaluation and future certification-oriented assessment of machine-learning protection functions.
Abstract:The increasing interest in data-driven methods for power system protection is accompanied by a lack of standardized, publicly available high-voltage waveform datasets that enable transparent and reproducible evaluation. To address this gap, this paper introduces the PROTECT-90 dataset, an open electromagnetic transient (EMT)-simulated reference benchmark for high-voltage fault studies with consistent digital-fault-recorder-like measurements, publicly released with this work. The dataset comprises 9,022 physically consistent short-circuit simulation episodes generated on a standardized 90 kV double-line topology with systematically documented domain randomization of grid operating points, line parameters, and fault conditions. For each episode, synchronized three-phase voltage and current waveforms are recorded at eight measurement locations and released together with structured, machine-readable metadata describing fault type, fault location, inception time, and operating conditions. All modeling assumptions, parameter ranges, and data-generation procedures are explicitly documented to ensure transparency and cross-study comparability. By combining physically grounded EMT simulation, balanced scenario coverage, and open accessibility, PROTECT-90 establishes a standardized foundation for reproducible benchmarking of protection-oriented signal processing and learning-based methods.
Abstract:Large collections of real-world disturbance recordings are increasingly available in transmission networks, but their value for power system protection and automated disturbance analysis is limited by the absence of precise event-onset annotations. In practice, field-recorded voltage and current waveforms contain switching operations, transformer energization, resonance, saturation, and other non-ideal effects that can obscure or mimic genuine fault signatures, making reliable fault inception detection difficult. This paper presents an training-free framework for fault inception detection in real-world transmission disturbance data. The method combines protection-domain indicators, robust median/MAD-based normalization, a low-latency transient path, and persistence-aware fusion and veto logic to distinguish fault-consistent disturbances from non-fault transients. We apply the framework to 12053 transmission-level recordings from the publicly available RTE database and further assess detector performance on a manually reviewed subset of 300 events. On the reviewed subset, the detector achieves 96.6% recall, 79.2% precision, and a median timing error of 4.2ms for matched detections. These results indicate that the proposed approach can support protection-oriented disturbance screening, relay and post-event analysis, and the creation of timestamp annotations for downstream data-driven monitoring tasks.
Abstract:The integration of renewable and distributed energy resources reshapes modern power systems, challenging conventional protection schemes. This scoping review synthesizes recent literature on machine learning (ML) applications in power system protection and disturbance management, following the PRISMA for Scoping Reviews framework. Based on over 100 publications, three key objectives are addressed: (i) assessing the scope of ML research in protection tasks; (ii) evaluating ML performance across diverse operational scenarios; and (iii) identifying methods suitable for evolving grid conditions. ML models often demonstrate high accuracy on simulated datasets; however, their performance under real-world conditions remains insufficiently validated. The existing literature is fragmented, with inconsistencies in methodological rigor, dataset quality, and evaluation metrics. This lack of standardization hampers the comparability of results and limits the generalizability of findings. To address these challenges, this review introduces a ML-oriented taxonomy for protection tasks, resolves key terminological inconsistencies, and advocates for standardized reporting practices. It further provides guidelines for comprehensive dataset documentation, methodological transparency, and consistent evaluation protocols, aiming to improve reproducibility and enhance the practical relevance of research outcomes. Critical gaps remain, including the scarcity of real-world validation, insufficient robustness testing, and limited consideration of deployment feasibility. Future research should prioritize public benchmark datasets, realistic validation methods, and advanced ML architectures. These steps are essential to move ML-based protection from theoretical promise to practical deployment in increasingly dynamic and decentralized power systems.
Abstract:The widespread use of sensors in modern power grids has led to the accumulation of large amounts of voltage and current waveform data, especially during fault events. However, the lack of labeled datasets poses a significant challenge for fault classification and analysis. This paper explores the application of unsupervised clustering techniques for fault diagnosis in high-voltage power systems. A dataset provided by the Reseau de Transport d'Electricite (RTE) is analyzed, with frequency domain features extracted using the Fast Fourier Transform (FFT). The K-Means algorithm is then applied to identify underlying patterns in the data, enabling automated fault categorization without the need for labeled training samples. The resulting clusters are evaluated in collaboration with power system experts to assess their alignment with real-world fault characteristics. The results demonstrate the potential of unsupervised learning for scalable and data-driven fault analysis, providing a robust approach to detecting and classifying power system faults with minimal prior assumptions.
Abstract:Germany's transition to a renewable energy-based power system is reshaping grid operations, requiring advanced monitoring and control to manage decentralized generation. Machine learning (ML) has emerged as a powerful tool for power system protection, particularly for fault detection (FD) and fault line identification (FLI) in transmission grids. However, ML model reliability depends on data quality and availability. Data sparsity resulting from sensor failures, communication disruptions, or reduced sampling rates poses a challenge to ML-based FD and FLI. Yet, its impact has not been systematically validated prior to this work. In response, we propose a framework to assess the impact of data sparsity on ML-based FD and FLI performance. We simulate realistic data sparsity scenarios, evaluate their impact, derive quantitative insights, and demonstrate the effectiveness of this evaluation strategy by applying it to an existing ML-based framework. Results show the ML model remains robust for FD, maintaining an F1-score of 0.999 $\pm$ 0.000 even after a 50x data reduction. In contrast, FLI is more sensitive, with performance decreasing by 55.61% for missing voltage measurements and 9.73% due to communication failures at critical network points. These findings offer actionable insights for optimizing ML models for real-world grid protection. This enables more efficient FD and supports targeted improvements in FLI.