on behalf of the PREDICTOM consortium
Abstract:Quantitative T2* maps have strong potential for biomarker discovery but are limited by long scan times, rendering them impractical in clinical settings. Significant acceleration can be achieved through undersampling in k-space combined with learning-based reconstruction. However, reconstruction artifacts and noise can propagate into downstream T2* fitting, degrading its accuracy. We introduce CUPA-T2*, a framework that explicitly propagates voxel-wise inter-echo uncertainty from stochastic Monte Carlo dropout reconstructions to downstream T2* fitting via covariance-aware sampling. T2* fitting is performed with a heteroscedastic MLP and a correlation-based regularizer that encourages alignment between predicted variance and reconstruction uncertainty. Experiments on accelerated brain MRI data show tissue-dependent behavior: CUPA-T2* achieves competitive overall T2* fitting performance and improves white-matter performance at higher accelerations. Compared with a heteroscedastic baseline, the proposed framework substantially increases alignment between reconstruction uncertainty and predicted T2* variance, while also revealing a trade-off with calibration (ECE) and selective prediction performance (AURC). CUPA-T2* enables reconstruction uncertainty-aware T2* fitting and delivers voxel-wise uncertainty maps to support the interpretation of quantitative T2* estimates.
Abstract:Multi-contrast MRI sequences allow for the acquisition of images with varying tissue contrast within a single scan. The resulting multi-contrast images can be used to extract quantitative information on tissue microstructure. To make such multi-contrast sequences feasible for clinical routine, the usually very long scan times need to be shortened e.g. through undersampling in k-space. However, this comes with challenges for the reconstruction. In general, advanced reconstruction techniques such as compressed sensing or deep learning-based approaches can enable the acquisition of high-quality images despite the acceleration. In this work, we leverage redundant anatomical information of multi-contrast sequences to achieve even higher acceleration rates. We use undersampling patterns that capture the contrast information located at the k-space center, while performing complementary undersampling across contrasts for high frequencies. To reconstruct this highly sparse k-space data, we propose an implicit neural representation (INR) network that is ideal for using the complementary information acquired across contrasts as it jointly reconstructs all contrast images. We demonstrate the benefits of our proposed INR method by applying it to multi-contrast MRI using the MPnRAGE sequence, where it outperforms the state-of-the-art parallel imaging compressed sensing (PICS) reconstruction method, even at higher acceleration factors.