Abstract:Top-Orthogonal-to-Bottom-Electrode (TOBE) arrays, also known as bias-switchable row-column arrays (RCAs), allow for imaging techniques otherwise impossible for non-bias-switachable RCAs. Hadamard Encoded Row Column Ultrasonic Expansive Scanning (HERCULES) is a novel imaging technique that allows for expansive 3D scanning by transmitting plane or cylindrical wavefronts and receiving using Hadamard-Encoded-Read-Out (HERO) to perform beamforming on what is effectively a full 2D synthetic receive aperture. This allows imaging beyond the shadow of the aperture of the RCA array, potentially allows for whole organ imaging and 3D visualization of tissue morphology. It additionally enables view large volumes through limited windows. In this work we demonstrated with simulation that we are able to image at comparable resolution to existing RCA imaging methods at hundreds of frames per second. We validated these simulations by demonstrating an experimental implementation of HERCULES using a custom fabricated TOBE array, custom biasing electronics, and a research ultrasound system. Furthermore, we assess our imaging capabilities by imaging a commercial phantom, and comparing our results to those taken with traditional RCA imaging methods. Finally, we verified our ability to image real tissue by imaging a xenograft mouse model.
Abstract:Row-Column Arrays (RCAs) offer an attractive alternative to fully wired 2D-arrays for 3D-ultrasound, due to their greatly simplified wiring. However, conventional RCAs face challenges related to their long elements. These include an inability to image beyond the shadow of the aperture and an inability to focus in both transmit and receive for desired scan planes. To address these limitations, we recently developed bias-switchable RCAs, also known as Top Orthogonal to Bottom Electrode (TOBE) arrays. These arrays provide novel opportunities to read out from every element of the array and achieve high-quality images. While TOBE arrays and their associated imaging schemes have shown promise, they have not yet been directly compared experimentally to conventional RCA imaging techniques. This study aims to provide such a comparison, demonstrating superior B-scan and volumetric images from two electrostrictive relaxor TOBE arrays, using a method called Fast Orthogonal Row-Column Electronic scanning (FORCES), compared to conventional RCA imaging schemes, including Tilted Plane Wave (TPW) compounding and Virtual Line Source (VLS) imaging. The study quantifies resolution and Generalized Contrast to Noise Ratio (gCNR) in phantoms, and also demonstrates volumetric acquisitions in phantom and animal models.