Abstract:Vision-language models trained with contrastive learning on paired medical images and reports show strong zero-shot diagnostic capabilities, yet the effect of training batch composition on learned representations remains unexplored for 3D medical imaging. We reproduce Merlin, a dual-encoder model that aligns 3D abdominal CT volumes with radiology reports using symmetric InfoNCE loss, achieving a zero-shot macro F1 of 74.45% across 30 findings (original: 73.00%). We then investigate two axes of variation. First, we control the normal-to-abnormal ratio within training batches at 25:75, 50:50, and 75:25 using section-level balanced sampling on the full dataset. All three configurations underperform the unbalanced baseline by 2.4 to 2.8 points, with 75:25 achieving the best result (72.02%) among balanced variants. Second, we conduct data scaling ablations on a 4,362-study subset, training with 20%, 40%, and 100% of the data. Performance scales sub-linearly from 65.26% to 71.88%, with individual findings varying dramatically in data sensitivity. Enforcing 50:50 balanced sampling on the same subset further degrades performance to 68.01%, confirming that explicit class balancing hurts regardless of dataset or balancing granularity. Our results indicate that the stochastic diversity of random sampling, combined with Merlin's alternating batching over anatomical subsections, provides more effective regularization than engineered class ratios at the small batch sizes required by 3D medical volumes.
Abstract:Background: Pancreatic cancer is one of the most aggressive cancers, with poor survival rates. Endoscopic ultrasound (EUS) is a key diagnostic modality, but its effectiveness is constrained by operator subjectivity. This study evaluates a Vision Transformer-based deep learning segmentation model for pancreatic tumors. Methods: A segmentation model using the USFM framework with a Vision Transformer backbone was trained and validated with 17,367 EUS images (from two public datasets) in 5-fold cross-validation. The model was tested on an independent dataset of 350 EUS images from another public dataset, manually segmented by radiologists. Preprocessing included grayscale conversion, cropping, and resizing to 512x512 pixels. Metrics included Dice similarity coefficient (DSC), intersection over union (IoU), sensitivity, specificity, and accuracy. Results: In 5-fold cross-validation, the model achieved a mean DSC of 0.651 +/- 0.738, IoU of 0.579 +/- 0.658, sensitivity of 69.8%, specificity of 98.8%, and accuracy of 97.5%. For the external validation set, the model achieved a DSC of 0.657 (95% CI: 0.634-0.769), IoU of 0.614 (95% CI: 0.590-0.689), sensitivity of 71.8%, and specificity of 97.7%. Results were consistent, but 9.7% of cases exhibited erroneous multiple predictions. Conclusions: The Vision Transformer-based model demonstrated strong performance for pancreatic tumor segmentation in EUS images. However, dataset heterogeneity and limited external validation highlight the need for further refinement, standardization, and prospective studies.
Abstract:Background: Reporting and Data Systems (RADS) standardize radiology risk communication but automated RADS assignment from narrative reports is challenging because of guideline complexity, output-format constraints, and limited benchmarking across RADS frameworks and model sizes. Purpose: To create RXL-RADSet, a radiologist-verified synthetic multi-RADS benchmark, and compare validity and accuracy of open-weight small language models (SLMs) with a proprietary model for RADS assignment. Materials and Methods: RXL-RADSet contains 1,600 synthetic radiology reports across 10 RADS (BI-RADS, CAD-RADS, GB-RADS, LI-RADS, Lung-RADS, NI-RADS, O-RADS, PI-RADS, TI-RADS, VI-RADS) and multiple modalities. Reports were generated by LLMs using scenario plans and simulated radiologist styles and underwent two-stage radiologist verification. We evaluated 41 quantized SLMs (12 families, 0.135-32B parameters) and GPT-5.2 under a fixed guided prompt. Primary endpoints were validity and accuracy; a secondary analysis compared guided versus zero-shot prompting. Results: Under guided prompting GPT-5.2 achieved 99.8% validity and 81.1% accuracy (1,600 predictions). Pooled SLMs (65,600 predictions) achieved 96.8% validity and 61.1% accuracy; top SLMs in the 20-32B range reached ~99% validity and mid-to-high 70% accuracy. Performance scaled with model size (inflection between <1B and >=10B) and declined with RADS complexity primarily due to classification difficulty rather than invalid outputs. Guided prompting improved validity (99.2% vs 96.7%) and accuracy (78.5% vs 69.6%) compared with zero-shot. Conclusion: RXL-RADSet provides a radiologist-verified multi-RADS benchmark; large SLMs (20-32B) can approach proprietary-model performance under guided prompting, but gaps remain for higher-complexity schemes.