Abstract:Food manufacturing requires reliable inspection systems to detect foreign material contamination and maintain product safety. Sub-THz transmission imaging provides material-dependent attenuation characteristics that are useful for detecting low-density contaminants in food products. However, existing unsupervised anomaly detection methods mainly rely on RGB-pretrained visual representations, which may not adequately capture the transmission behavior of Sub-THz images. This paper proposes a Beer-Lambert guided representation learning framework for unsupervised anomaly detection in Sub-THz food inspection images. The proposed method introduces an attenuation decomposition module as an auxiliary regularization module that constrains student representations through attenuation reconstruction during training. In addition to the conventional one-class setting, we introduce a Leave-One-Food-Out protocol to evaluate generalization capability under unseen food categories. Experimental results on the Inline-Food-Inspection-THz dataset show that the proposed method improves overall anomaly detection performance over the baseline method.
Abstract:Collision avoidance systems have evolved toward camera-based deep learning approaches for driving scene understanding. However, deployment in edge environments such as country clubs is constrained by limited computational resources and unreliable communication infrastructure. Moreover, constructing large-scale datasets for the target domain involves substantial annotation cost. To address these limitations, we propose an instance-aware knowledge distillation framework for semi-supervised learning. Specifically, we generate pseudo labels that mitigate teacher bias by leveraging domain priors from the teacher and instance-centric knowledge from foundation models. The trained lightweight student is deployed in the proposed collision avoidance system and performs multiple dense prediction tasks in real-time. The system detects frontal obstacles and encodes their spatial information into controller area network messages for automated guided vehicle operation. To achieve this, we construct a large-scale country club dataset and perform field validation of the proposed system. Experimental results demonstrate that the student outperforms the large teacher in instance segmentation while mitigating performance degradation in monocular depth estimation. Compared with the teacher, the student reduces FLOPs by 22.68$\times$ and parameters by 14.33$\times$, achieving 6.46 FPS on a low-cost edge device.
Abstract:Human health can be critically affected by cardiovascular diseases, such as hypertension, arrhythmias, and stroke. Heart rate and blood pressure are important biometric information for the monitoring of cardiovascular system and early diagnosis of cardiovascular diseases. Existing methods for estimating the heart rate are based on electrocardiography and photoplethyomography, which require contacting the sensor to the skin surface. Moreover, catheter and cuff-based methods for measuring blood pressure cause inconvenience and have limited applicability. Therefore, in this thesis, we propose a vision-based method for estimating the heart rate and blood pressure. This thesis proposes a 2-stage deep learning framework consisting of a dual remote photoplethysmography network (DRP-Net) and bounded blood pressure network (BBP-Net). In the first stage, DRP-Net infers remote photoplethysmography (rPPG) signals for the acral and facial regions, and these phase-shifted rPPG signals are utilized to estimate the heart rate. In the second stage, BBP-Net integrates temporal features and analyzes phase discrepancy between the acral and facial rPPG signals to estimate SBP and DBP values. To improve the accuracy of estimating the heart rate, we employed a data augmentation method based on a frame interpolation model. Moreover, we designed BBP-Net to infer blood pressure within a predefined range by incorporating a scaled sigmoid function. Our method resulted in estimating the heart rate with the mean absolute error (MAE) of 1.78 BPM, reducing the MAE by 34.31 % compared to the recent method, on the MMSE-HR dataset. The MAE for estimating the systolic blood pressure (SBP) and diastolic blood pressure (DBP) were 10.19 mmHg and 7.09 mmHg. On the V4V dataset, the MAE for the heart rate, SBP, and DBP were 3.83 BPM, 13.64 mmHg, and 9.4 mmHg, respectively.